Wall-Mount Heatless Desiccant Compressed Air Dryers
Compact design and maximum performance. Dew points from -40 °F (-40 °C) standard to -100 °F (-70 °C). Wide range of models available. CRN-approved.
All models are designed and manufactured locally in our Cambridge, Ontario facility. Many custom options available.
Features
- Powder-coated steel construction towers
- Towers are pressure rated to 580 PSIG, MAWP
- Easy desiccant replacement through plugged fill and drain ports
- Plated steel hydraulic pipe fittings and S/S schedule-40 pipe nipples
- S/S 3-way inlet valve with position indication
- Poppet-style diaphragm-operated purge exhaust valves
- S/S control air solenoid valves
Optional Features and Equipment
- Oil coalescing prefilters (with optional coarse filter inline prior to fine coalescer)
- Particulate afterfilter to remove desiccant fines
- Activated charcoal final filter
- Bypass valve and filter mounting
- Floor stand
- Smaller-size purge orifice for lower capacities to reduce/save purge air requirements
- ‘Purge while pumping only’ controls when compressor is running/loaded
- Purge economizer controls: Reduces purge flow based on dew point-controlled purging
- Tower switching failure alarm: Monitors tower pressure to ensure depressurization and repressurization within required time frames
- High humidity alarm with optional audible buzzer
- High or low pressure alarm
- High pressure options
Applications
- Automotive
- Pharmaceutical
- Power Stations
- Instrumentation
- Packaging
- Food Processing
- Industrial compressed air
Standard Control Features
- Microprocessor controls
- Consistent dew point: Purge air consumption controlled through fixed orifice
- Cycle pre-programmed to 10 minutes
- Easily adjustable to 4 minutes for desired dew points of up to -70 °C
- Correct precision purge orifices to achieve maximum efficiency for dryer’s capacity
Custom Options Available
1 year warranty included
Model Number | Capacity CFM100psig | Depth | Height | Inlet and Outlet Size | Purge Air Consumption | Weight | Width | Maximum Operating Pressure | Pressure Dew Point | Inlet Temperature | Ambient Tempearture Range | Maximum Pressure Drop | Brochure PDF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AP-8 | 8 | 8.75 | 41.75 | 1/4" NPT | 15% | 55 | 20 | 150 psig | -40°C | 38°C | 5 to 40°C | 3 psig | Download |
AP-16 | 16 | 9.5 | 45 | 1/2" NPT | 15% | 77 | 20 | 150 psig | -40°C | 38°C | 5 to 40°C | 3 psig | Download |
AP-30 | 50 | 13 | 45 | 1/2" NPT | 15% | 160 | 28 | 140 psig | -40°C | 40°C | 5 to 40°C | 3 psig | Download |
AP-50 | 50 | 13 | 45 | 1/2" NPT | 15% | 160 | 28 | 150 psig | -40°C | 38°C | 5 to 40°C | 3 psig | Download |
AP-75 | 75 | 13 | 44 | 3/4" NPT | 15% | 190 | 34 | 140 psig | -40°C | 40°C | 5 to 40°C | 3 psig | Download |